Chasis mounting toroidal transformer 230V/ 24V 115-0-115V

Tianyi toroidal transformers, manufactured and tested in compliance with EN61558. Designed and prepared for II class equipment. Suited for power supply circuitry of electric machines and electronics devices with low nonload losses and weight. To produce them, we use the most mordern machines, which guarantees very tightly wound coil and high electrical performance.

1. Features

-Conform to EN61558-1, EN61558-2-6, UL1446

-Extremly low stray-magnetic-field

-Efficient reduction of costs and energy

-Temperature rise is below 60°

-Temperature fuse (130°) integrated in primary winding 

2. Technical Parameters

Power Size                              3W 5W10W 15W 20W 30W
Primary Voltage                       230V/115-0-115V
Secondary Voltage                  12V
Working Frequency                  50/60 Hz
Thermal Switch                        130° (Automatically Reset)
Insulation Class                        B Class (130°)
Pri-Sec Isolation                       4KV
Max Temperature                     60°

3. Standard Size

Rated PowerEfficiencyNo-load LossDiameterHeightWeight
15VA86%0.31W59mm40mm0.42Kg
30VA86%0.43W70mm38mm0.54Kg
50VA86%0.52W81mm43mm0.71Kg
75VA86%0.60W94mm41mm0.95Kg
100VA87%1.14W92mm57mm1.34Kg
150VA90%1.37W119mm46mm2.12Kg
200VA91%1.95W121mm60mm2.84Kg
250VA92%2.02W132mm57mm3.24Kg
300VA93%2.10W132mm62mm3.58Kg
500VA94%3.12W158mm64mm5.50Kg
750VA96%4.84W169mm80mm7.58Kg
1000VA96%6.94W202mm75mm10.42Kg
2000VA98%11.42W208mm89mm16.34Kg

 

Note: The standard input is dual 110V ac windings, parallel connected for 110V ac, or series for 220V ac. As for larger power size, do not hesitate to request the details from us.

4. Custom Design

Do not see what you're looking from our standard catalog, just send inquiry to assist you in designing a custom toroidal transformer for your project. Refer to the following information to get started.

 

 

(1) Insulation System - Our standard is Ul approved class B (130°). Options include UL class A (105°), class F (155°), class H (180°), or to suit.

(2) Temperature Rise - Typically we design for 60° rise, but can be application dependant. This yields the size and regulation specs listed in the standard line.

(3) Input Sides - As these are application specific, we have several traditional input configurations for both 50Hz and 60Hz, which are described in our standard line. Optionally, we can design for 10 - 400Hz using goss cores, and will select appropriate materials, as higher F is needed.

(4) Power Size - No factory limits are implied, but typically we can design and manufacture single-phase toroids up to 10000VA.

(5) Duty Cycle - Significant reductions in transformer size and weight may be realized in most cases where the transformer is loaded intermittently. Duty cycle is an important design consideration.